Page image

n. 15a

16

No. 3.—Return of Notices given to repair Boilers — continued.

■lumber. Type- Description of Repairs. Type. Description of Repairs. _! j I ; Portable .. Two rows of screwed stays renewed in firebox. I .. .. Two rows of screwed stays renewed in throat-plate. 1 .. . . Wasted part of foundation-ring patched. 1 Semi-portable . . Four new screwed stays fitted in firobox. 1 .. .. One new longitudinal stay fitted. 2 .. .. Patches fitted in firebox. 1 „ .. Retubed. .1 Semi-tubular .. New compensating-ring fitted to manhole-opening. 1 .. .. New dog and stud fitted to mud-door. 1 ,, . . New studs fitted in mud-door. 2 ,, . . Patches renewed. 5 „ .. Retubed. 1 .. . . Several new nuts fitted on stay-tubes. 1 .. .. Several new screwed stays fitted in furnace. 1 .. . . Two new grider-stays fitted. 1 „ . . Two new pins in longitudinal stays. I Traction A number of new screwed stays fitted in firebox. t> .. . . j Compensating-rings fitted to manhole-openings. I ,j .. Compensating-ring fitted to manhole-opening, and seven new tubes fitted. I .. .. Compensating-rings fitted to mudhole-openings. 1 .. .. Coupling-pins in longitudinal stays renewed. 1 .. . . Cracks in side of firebox chain-pinned. I .. . . Eighteen new screwed stays fitted in firebox. 1 ., . . Firebox-crown repaired. I .. . . Five new screwed stays fitted in throat-plate. I .. .. j Five new tubes fitted. 1 .. .. New dogs fitted to manhole-door. 2 .. . . New firebox fitted. 1 .. . . New firebox fitted, three new stay-tubes and new coupling-pins in longitudinal stays. 2 .. . . New mud-doors fitted. '2 „ .. New studs fitted in manhole-door. I .. .. One new girder-stay fitted. I „ . . Patch fitted on crown of firebox. :i .. . . Patches fitted in firebox. I .. .. Patches fitted on foundation-ring. I .. .. Patch fitted on shell under blow-off cock. 1 .. .. Plughole retapped, and new tapered plug fitted. 10 .. .. Retubed. 2 .. . . Retubed. and new fireboxes fitted. 1 .. .. Retubed, end new studs fitted in manhole-door. 2 .. .. Retubed. and new firebox-crown fitted. 1 .. . . Retubed, thirty-six new screwed stays fitted in firebox, new studs in manhole-door, and compensating-ring fitted round manhole-open-ing. I .. . . Seven new lubes and four new screwed stays fitted in firebox. 8 .. .. Several new ecrewed stays fitted in firebox. 1 .. .. Several new tubes fitted. I ,, .. Sixteen new screwed stays fitted in firebox. 1 ,. .. Ten new tubes fitted. 2 .. .. Tubes expanded. I .. . . Tubes in firebox-end expanded. 1 .. . . Twenty-four new screwed stays fitted in firebox. 1 Vertical cross-tiil),' A row of n< w screwed stays fitted round firebox. 2 .. Angle-collar renewed round uptake. I .. Compensating-ring fitted round manhole-opening. 5 .. Compensating-rings fitted round mudhole-openings. I .. Compensating-ring fitted round mudhole-opening, and new collar round uptake. 1 .. Manhole-door repaired. 2 .. New manhole-doors fitted. -t .. New mudhole-doors fitted. 1 .. New spigot fitted to manhole-door. 1 .. New studs fitted to mudhole-door. ' t ' .. New vertical stays fitted. 1 ,, Patches fitted in firebox.

Log in or create a Papers Past website account

Use your Papers Past website account to correct newspaper text.

By creating and using this account you agree to our terms of use.

Log in with RealMe®

If you’ve used a RealMe login somewhere else, you can use it here too. If you don’t already have a username and password, just click Log in and you can choose to create one.


Log in again to continue your work

Your session has expired.

Log in again with RealMe®


Alert