Extensions wore made during the year at Lake Coleridge (3,000 kw., water-power), Wellington (5,000 kw., steam), and Auckland (5,000 kw., steam). The changes during the coming year will also be in the direction of increasing the large stations and closing down the small ones, giving greater economy in operation. The total installed capacity has increased during the year by 8,365 kw., or 14*5 per cent, (from 57,589 kw. to 65,954 kw), while the sum of the maximum loads has decreased by 390 kw., or less than 1 per cent, (from 54,502 kw. to 54,112 kw.). This is due to the concentration of the peak load into a lesser number of stations. The proportion of installed plant is now as follows : — Stations. Kilowatts. n ', per Cent. Water-power .. '.. .. ..30 30,392 46-1 Steam-power .. .. .. ..8 30,085 45-6 Gas-power .. .. .. .. ..18 4,621 7-0 Oil-power .. .. .. .. ..2 856 1-3 58 65,954 100-0 This increase in the proportion of steam-power is due to the addition of units in the Auckland and Wellington stations, pending completion of the Government hydro-electric stations. Next year the proportion of water-power will be considerably increased. The number of consumers supplied has increased from 106,790 to 124,705, an increase of 17,915, or 17 per cent., for the year. The units per consumer were 1,394, as compared with 1,280 last year. The total population included in the various areas of electric-power supply is 824,030, or over 61 per cent, of the total population of the Dominion ; so that the ideal of a supply being available to every home in the Dominion is well on the way to realization. The maximum demand per head of population in the areas supplied is 0-066 kw., practically onehalf of the allocation of 0-15 kw., or 0-2 h.p. per head of population, which is the basis of the design of the Government schemes. The units sold per head of population supplied were 211, as compared with 178 last year. The total length of distributing-line is 4,878 route-miles, as compared with 3,758 last year, an increase of 1,120 miles, or 30 per cent. The number of consumers per route-mile is 25-6, as compared with 28-4 last year, the reduction being due to the largo mileage of new lines erected during the year to which the full number of services are not yet connected. Tho power-demand per route-mile of line is now 11 kw., the sales 35,648 units, and the revenue £292. These are substantially smaller than last year, for the same reason, but are still remunerative returns over the whole business. The revenue per kilowatt of output of all stations was £26-3, as compared with £24-2 last year. The water-power stations show a revenue of £23-1 per kilowatt, steam stations of £30-9 per kilowatt, and gas stations of £328 per kilowatt. These are valuable figures for use in forecasting the revenue from systems of various descriptions. The water-power systems include the largest proportion of large consumers, and the gas-engine stations the largest proportion of small consumers. Out of the eighty-three distributing authorities, sixty showed a profit for the year amounting to £170,939, and twenty-three showed a loss amounting to £26,213. The general result is a net profit for the whole Dominion of £144,726 after paying working-costs (£715,441) and capital charges (£563,218) at the rate of 7-2 per cent, on the total capital outlay of £7,822,034. This shows a net profit of 1-85 per cent., as compared with 1-7 per cent, last year. The business on the whole is thus a thoroughly sound and remunerative one, as well as supplying a public necessity to 61 per cent, of the population of tho Dominion.
Electric-power Supply of New Zealand for the year ended 31st March, 1924.
Water. Steam. Gas. on. Total. Number of stations Average capacity (kilowatts) Number of consumers Installed capacity (kilowatts), (main plant only) Maximum load (kilowatts) Units generated Annual load-factor (per cent.) .. Units sold Total capital outlay* Total capital per kilowatt installed* Total annual working-costs Total annual working-cost per unit sold .. Total annual working-cost per kilowatt, maximum load Total annual capital charges Total annual capital charges per unit sold Total annual capital charges per kilowatt, maximum load Total annual capital charges, percentage of capital outlay Total annual costs Total annual costs per unit sold Total annual cost per kilowatt, maximum load Total annual revenue Total annual revenue per unit sold Total annual revenue per kilowatt, maximum load Net profit 30 1,013 71,397 30,392 32,949 152.302,799 52-8 120,617,414 £4,985,857 £164 £315,231 0-63d. £9-6 £350,651 0-70d. £10-6 8 3,761 40,144 30,085 17,522 50,312,793 36-7 46,712,494 £2,162,342 £72 £317,156 l-63d. £18-1 £183,075 0-94d. £10-4 18 257 9,995 4,621 2,949 6,658,394 25-8 5,272,399 £594,720 £129 £69,249 3-15d. £23-5 £23,429 l-07d. £7-9 2 428 3,169 856 692 1,535,445 25*3 1,292,985 £79,115 £92 £13,805 2-56d. £19-9 £6,063 l-12d. £8-8 58 1,137 124,705 65,954 54,112 216,809,431. 45-7 173,895,292 £7,822,034 £119 £715,441 0-99d. £13-2 £563,218 0-78d. £10-4 7-03 8-47 3-94 7-66 7-20 £665,882 l-33d. £20-2 £500,231 2-57d. £28-5 £92,67.8 4-22d. £31-4 £19,868 3-69d. £28-7 £1,278,659 l-77d. £23-6 £760,587 l-51d. £23-1 £541,225 2-78d. £30-9 £96,605 4-40d. £32-8 £24,968 4-63d. £36-1 £1,423,385 l-96d. £26-3 £94,705 £40,994 £3,927 £5,100 £144,726 • Includi dii Ibui
Use your Papers Past website account to correct newspaper text.
By creating and using this account you agree to our terms of use.
Your session has expired.