Page image

H.—lsa

No. 3.—Return of Notices given to repair Boilers — continued.

3—H. 15a.

17

Number. Type. Description of Repairs. 2 3 3 4 3 1 1 1 1 1 1 1 Locomotive 33 33 3, 33 33 33 33 Crown stay-nuts renewed. Fifteen new tubes fitted. New firebox fitted. New tube-plate, new barrel, and retubed. One hunderd new tubes fitted. Patches fitted in firebox under door. Patches renewed. Retubed. Several new nuts fitted to crown-stays. Several new screwed stays fitted in firebox. Sixteen new screwed stays fitted in firebox. Thirty-nine new screwed stays fitted in firebox. Twelve new screwed stays fitted in firebox, and patch under door. Twenty-four new nuts fitted to crown-stays. Twenty-four new screwed stays fitted in firebox. Twenty tubes renewed. Two new longitudinal stays fitted, and compensating-ring round mudhole-opening. Two patches fitted on external firebox, and retubed. Two patches renewed in firebox. New bottom fitted to inner shell. New tube fitted. Several rivets renewed. Landings on bottom caulked. Bottom back end-plate cut out of shell, and new plate fitted. Brickwork repaired. Brickwork repaired, and new hanger fitted to boiler. Bulge cut out of bottom of shell, and patch riveted on. Circumferential seam reriveted. Compensating-rings fitted round manhole-openings. Compensating-rings fitted round mudhole-openings. Compensating-ring fitted round mud-hole opening, and new door fitted. 1 1 1 1 1 1 2 6 1 1 1 2 11 1 Manure-dryer 33 Marine Multitubular 2 1 1 1 1 1 1 1 1 1 1 4 2 3 1 4 4 1 13 2 1 3 1 2 1 1 1 2 2 1 2 4 1 2 Compensating-rings round manhole-openings reriveted. Crown plate of steam-dome patched. Dog and stay fitted to bulge in bottom. Doubling plate fitted under hanger at back end of boiler. Eleven rivets in gusset-stays renewed. End seam reriveted. Fifteen new rivets put in circumferential seam. Fifteen new tubes and one new longitudinal stay fitted. Four stays fitted where tube-plate bulged. Gusset-stay angle-irons renewed. Large patch fitted on bottom at back end. Manhole-doors repaired. Manhole-door spigots reriveted. Mudhole-doors repaired. New back tube-plate fitted. New manhole-doors. New manhole-door, and compensating-ring fitted round opening. New manhole-door, and compensating-ring reriveted. New mudhole-doors. New mudhole-doors and compensating-ring fitted. New mudhole-door and new spigot for manhole-door. New studs fitted in mud-doors. One new longitudinal stay fitted. Opening for manhole dressed out, and new door fitted. Part of bottom shell renewed. Patch fitted on boiler-bottom where bulge cut out. Patch fitted on boiler under hanger-bracket, and new bracket fitted. Patch fitted on front tube-plate. Patch fitted over wasted part of longitudinal seam. Patch on bottom of shell reriveted. Patches renewed. Retubed. Retubed and bottom of shell repaired. Retubed, and compensating-ring fitted to mud-door.