Page image

H.—lsa.

No. 2.—Return of Defects— continued.

10

Description of Defects. Dangerous. Defective in Lesser Degree. Total. Gusset stays defective Laminated plates in bottom of shell - ... Laminated plate in furnace Leaking at corners of foundation-ring Longitudinal stays wasted Manhole-doors bad Manhole-door rivetting bad Manhole-door spigots defective Manhole-openings in shell wasted ... Mudhole-doors bad Mudhole-door dogs bad Mudhole-door studs bad ... Nine rivets in front tube-plate defective Nine tubes bad ... One hundred and six screwed stays bad One longitudinal stay bad Patches defective Pitting badly in places Pitting on crown of firebox Pitting on crown of firebox (pressure reduced) Pitting slightly internally ... Eivets in gusset stays defective Bivets in manhole compensating-ring bad Bivets in mud-drum flange defective Bivets in tube-plate defective Seams leaking Several rivets bad in furnace Several rivets bad in shell... Several rivets in foundation-ring bad Several screwed stays in firebox bad Several stay-nuts on firebox-crown bad Several tubes bad Shell wasted at circumferential seams Shell wasted at crown of boiler Shell wasted at manhole-openings ... Shell wasted at mudhole-openings ... Shell wasted considerably... Shell wasted externally Shell wasted where blow-off cocks jointed to boiler Shell wasted where check-valve chests jointed to boiler Shell wasted where safety-valve chests jointed to boiler Shell wasted where stop-valve chests jointed to boiler... Six nuts on girder-stays bad Sixteen screwed stays in firebox bad Sixteen tubes bad Sixty-two screwed stays in firebox bad Stay-nuts on back tube-plate defective Steam-dome flange defective Ten screwed stays in firebox bad ... Ten tubes bad Thirteen screwed stays in firebox bad Thirty-eight tubes bad Thirty screwed stays in firebox bad Thirty-six screwed stays in firebox bad Throat-plates thin Top row of tubes bad Top tube-plates thin Top tube-plates thin (pressure reduced) Tubes bad Tube-ends leaking Tube-plates bad ... Tube-plates bulged Tube-plates wasted Tube-plates wasted (pressure reduced) Twelve screwed stays in firebox bad Twelve tubes bad Twenty-eight screwed stays in firebox bad ... Twenty-five screwed stays in firebox bad 2 3 1 1 3 12 1 11 13 34 3 11 1 1 2 3 1 1 3 12 1 11 13 34 3 11 1 1 1 5 15 4 3 1 14 4 1 1 1 9 1 11 1 17 1 28 3 1 1 82 1 6 7 2 6 4 1 1 1 1 1 1 1 2 1 1 1 1 3 1 12 2 90 2 8 1 13 2 2 2 2 2 5 15 4 3 1 14 4 1 1 1 9 1 11 1 17 1 28 3 1 1 82 1 6 7 2 6 4 1 1 1 1 1 1 2 1 1 1 1 3 1 8 2 90 2 1 13 2 2 2 2 2